NERC CIP Standards: What They Mean for Your Organization
The NERC Critical Infrastructure Protection (CIP) Reliability Standards are mandatory cybersecurity and physical security rules for registered entities with Bulk Electric System assets.
The NERC Critical Infrastructure Protection (CIP) Reliability Standards are mandatory cybersecurity and physical security rules for registered entities with Bulk Electric System assets.
NERC CIP applies to registered entities with BES Cyber Systems. CIP-002 sorts those systems into high, medium or low impact, and that category drives which requirements apply. Several new versions are approved and take effect between 2028 and 2029, so programs need to plan ahead. ALCON DTS supports the IT and security side of CIP programs, working alongside your compliance team.
The CIP standards are part of NERC’s mandatory Reliability Standards. They cover how registered entities identify, protect, monitor and recover the cyber systems that support the Bulk Electric System (BES).
NERC defines the BES as: “Unless modified by the lists shown below, all Transmission Elements operated at 100 kV or higher and Real Power and Reactive Power resources connected at 100 kV or higher. This does not include facilities used in the local distribution of electric energy.”
The definition then lists inclusions, such as Blackstart Resources and certain generating resources at 100 kV or above, and exclusions, such as certain radial systems and local networks. NERC adds: “Elements may be included or excluded on a case-by-case basis through the Rules of Procedure exception process.”
NERC registers entities by function. CIP-002-5.1a applies to these registered functions:
Inverter-based resources. Since May 15, 2026, NERC requires registration for entities that own and operate certain non-BES inverter-based resources with an aggregate nameplate capacity of 20 MVA or more, connected at 60 kV or more. NERC has not yet set CIP compliance dates for these newly registered resources.
Whether your facilities are part of the BES, and how they are registered, is a decision for your compliance team and NERC.
CIP-002 is the starting point. Each registered entity must categorize its BES Cyber Systems as high, medium or low impact, and review those identifications with CIP Senior Manager approval at least once every 15 calendar months.
The full criteria are in CIP-002-5.1a, Attachment 1.
| Standard | Topic | In force now | Approved next version |
|---|---|---|---|
| CIP-002 | BES Cyber System categorization | CIP-002-5.1a | CIP-002-8 (7/1/2028) |
| CIP-003 | Security management controls, including low impact | CIP-003-9 (since 4/1/2026) | CIP-003-10 (7/1/2028); CIP-003-11 (7/1/2029) |
| CIP-004 | Personnel and training; access to BES Cyber System Information | CIP-004-7 | CIP-004-8 (7/1/2028) |
| CIP-005 | Electronic security perimeters and remote access | CIP-005-7 | CIP-005-8 (7/1/2028) |
| CIP-006 | Physical security of BES Cyber Systems | CIP-006-6 | CIP-006-7.1 (7/1/2028) |
| CIP-007 | Systems security management | CIP-007-6 | CIP-007-7.1 (7/1/2028) |
| CIP-008 | Incident reporting and response planning | CIP-008-6 | CIP-008-7.1 (7/1/2028) |
| CIP-009 | Recovery plans | CIP-009-6 | CIP-009-7.1 (7/1/2028) |
| CIP-010 | Configuration change management and vulnerability assessments | CIP-010-4 | CIP-010-5 (7/1/2028) |
| CIP-011 | Information protection | CIP-011-3 | CIP-011-4.1 (7/1/2028) |
| CIP-012 | Communications between Control Centers | CIP-012-2 (since 7/1/2026) | none listed |
| CIP-013 | Supply chain risk management | CIP-013-2 | CIP-013-3 (7/1/2028) |
| CIP-014 | Physical security of key transmission stations | CIP-014-3 | CIP-014-4 (10/1/2028) |
| CIP-015 | Internal network security monitoring | not yet enforceable | CIP-015-1 (10/1/2028); CIP-015-2 (10/1/2029) |
NERC is the Electric Reliability Organization. It runs its Compliance Monitoring and Enforcement Program with the Regional Entities. For the ERCOT region, the Regional Entity is Texas RE.
Monitoring methods include Compliance Audits, Self-Certifications, Spot Checks, Compliance Investigations, Self-Reports, Self-Logging, Periodic Data Submittals and Complaints. NERC says “Self-Reports are encouraged at the time a Registered Entity becomes aware that it has, or may have, violated a Reliability Standard.”
Penalties are assessed under the NERC Sanction Guidelines and filed with FERC. The federal maximum is currently $1,584,648 per violation, per day (18 CFR 385.1602), and FERC adjusts it for inflation.
You keep the compliance decisions. ALCON DTS supports the IT and security side of your CIP program, working alongside your compliance team. Work on assets inside an electronic security perimeter, and on operational technology, stays with your operations and compliance staff.
| CIP area | How ALCON DTS supports you |
|---|---|
| CIP-002 categorization | Asset inventory support for IT systems, and organizing the evidence your compliance team requests |
| CIP-003 security management | Policy drafting support, MFA and identity for corporate IT and remote access tools, and vendor access documentation |
| CIP-004 personnel and training | General security awareness training, identity and access workflows for IT systems, and access review evidence |
| CIP-005, CIP-007 and CIP-010 | Patch management and logging for IT systems, and network segmentation design support for the IT side |
| CIP-008 and CIP-009 | Incident response planning, tabletop exercise support for IT scenarios, and recovery planning for IT systems |
| CIP-011 information protection | Data classification support, encryption and access controls for corporate file storage |
| CIP-013 supply chain | Vendor inventories, questionnaires and vendor risk documentation |
Our Security Monitoring (SIEM) service and our Backup and Disaster Recovery service are each quoted on their own. The exact controls in your environment depend on your ALCON DTS plan and any project work, and our expert team will show you which controls are in place today and which would add coverage. Your organization keeps control of its compliance program, and ALCON DTS supports the IT and security side. ALCON DTS does not audit, certify or validate CIP compliance.
Want to see where your IT side stands? Our expert team will walk through your corporate IT controls with you and help organize the IT evidence your compliance team asks for.
Last reviewed: October 27, 2026
This page is general information about the NERC CIP Reliability Standards, not legal or compliance advice for your situation.
Want a clearer picture of the IT side of your CIP program? Our expert team will walk through your corporate IT environment with you, show you the controls in place today and suggest next steps for the IT side.